Optima-518-Classic
The Optima - 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.
The Optima - 518 Classic, based on active's GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue's TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.
GEM - Geometrical Energy Management
Khác với các thương hiệu thiết bị IPL khác, Optima-518 dựa trên công nghệ GEM được cấp bằng sáng chế, công nghệ GEM là cách độc nhất để chuyển tải một năng lượng đến chính xác mục tiêu định trước. Công nghệ GEM là một phương pháp tập trung phần lớn năng lượng trên một bề mặt da, chọn lọc nhắm mục tiêu tới các nang lông, các đốm sắc tố, mụn..vv.. Vì vậy, không cần cung cấp quá nhiều năng lượng quá mức đến da (như các hệ thống khác) và Optima-518 chính là chìa khóa cho phương pháp điều trị da nhẹ nhàng và hoàn toàn không đau.
New Handpiece Design
[Handpiece optima] The Optima - 518 Classic is the first model to use the new Mark II multipurpose handpiece which enables:
Faster treatments - up to 0.5 Seconds between pulses.
Real-time handpiece temperature control.
Contemporary and stylish design.
Light weight design - 25% less weight to improve the therapists' comfort.
Large spot size
The larger the spot size the better the efficiency and speed of treatment. Crystal's spot is amongst the largest in the market, enabling a highly efficient usage of energy and promising a safe and painless treatment. In comparison with needle epilation, the Crystal 512 is 60 times faster.
Research Program
For clinical investigations, the self setting program allows researchers to set the treatment's parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31J\cm2 with high intensity of 4,000W.
* CE-MDD International Medical Standard
* FDA US Safety Standard
* IEC 601-1 Medical Safety Standard
* TGA Australian Medical Standard
* CFS Governmental (Health) Approval
* FCC US RDF Standard
* ISO 13485 Quality Medical Production
* ISO 9001 Quality Management Standard
* CSA Can.& US Safety App
Lamp's Life Span |
200,000 Flashes |
Wavelength |
420-1100 nm |
Treatment area |
7.5cm2(15*50 mm) |
Output Power |
11-22 joule/cm2 4,000 W |
Pulse Interval/Repetition Rate |
0.5~2.5 sec. |
Handpiece |
Universal Broad Wavelength System Mark II |
Operation Voltage |
230VAC / 110VAC |
Weight |
40Kg (including stand) |
Dimensions |
44cm x 45cm x 100cm (L x W x H) |